Skip to main content

FLOODED DEEP CYCLE BATTERY

6 FS GC-SC

Series FS Warranty 1 Year
Volts 6 Design GC2
Cells 3 Plates/Cell 19
Terminal Type DT
Included Hardware Stainless Steel K-Lock Nut
Size & Thread 5/16"-18
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Recommended Charge Current 30 A
Maximum Charge Current 50 A
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 703
Marine Crank Amps (MCA) 32°F / 0°C 879
Reserve Capacity (RC @ 25A) 465 Minutes
Reserve Capacity (RC @ 75A) 122 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 307 AH 3.07 A
@ 72 Hour Rate 302 AH 4.20 A
@ 50 Hour Rate 286 AH 5.71 A
@ 20 Hour Rate 240 AH 12.00 A
@ 15 Hour Rate 228 AH 15.20 A
@ 10 Hour Rate 211 AH 21.12 A
@ 8 Hour Rate 206 AH 25.80 A
@ 5 Hour Rate 190 AH 37.92 A
@ 1 Hour Rate 96 AH 96.0 A

Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F).
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 30.0 kg 66.0 lbs
Length 259 mm 10.19"
Width 181 mm 7.13"
Height Incl. Term. 279 mm 11"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Electrolyte Reserve 57 mm 2.25"
Container Polypropylene
Cover Polypropylene
Handles Top Molded Strap Brackets
  • Plastics are UL94 HB (UL94-V2 available)
  • Plastics are impact copolymer rated to ASTM D256, D5420
  • Vented design with integral flame arrestor vent caps

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

Rev.#3 | August 2024