Skip to main content

FLOODED DEEP CYCLE BATTERY

S6 L16-EX

Series 4500 Warranty 4 Years
Volts 6 BCI L16
Cells 3 Plates/Cell 11
Terminal Type LT
Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer
Size & Thread 5/16"-18
Cables Optional: 19" 4/0 interconnect cable
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Recommended Charge Current 45 A
Maximum Charge Current 70 A
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 871
Marine Crank Amps (MCA) 32°F / 0°C 1088
Reserve Capacity (RC @ 25A) 890 Minutes
Reserve Capacity (RC @ 75A) 297 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 479 AH 4.79 A
@ 72 Hour Rate 453 AH 6.29 A
@ 50 Hour Rate 429 AH 8.57 A
@ 20 Hour Rate 371 AH 18.55 A
@ 15 Hour Rate 345 AH 23.00 A
@ 10 Hour Rate 330 AH 33.02 A
@ 8 Hour Rate 319 AH 39.88 A
@ 5 Hour Rate 297 AH 59.36 A
@ 1 Hour Rate 167 AH 166.95 A

Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F).
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 59 kg 130 lbs
Length 31.8 cm 12.5"
Width 18.1 cm 7.13"
Height Inc. Term. 42.55 cm 16.75"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Electrolyte Reserve 57 mm 2.25"
Container High Density Polypropylene
Cover High Density Polypropylene
Handles Rope / Plastic Handle

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

Rev.#2 | May 2019