Skip to main content

FLOODED DEEP CYCLE BATTERY

S6 GC2-HC

Series 4000 Warranty 3 Years
Volts 6 BCI GC2
Cells 3 Plates/Cell 17
Terminal Type DT
Included Hardware Stainless Steel K-Lock Nut
Size & Thread 5/16"-18
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Recommended Charge Current 30 A
Maximum Charge Current 45 A
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 625
Marine Crank Amps (MCA) 32°F / 0°C 781
Reserve Capacity (RC @ 25A) 466 Minutes
Reserve Capacity (RC @ 75A) 117 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 308 AH 3.08 A
@ 72 Hour Rate 304 AH 4.22 A
@ 50 Hour Rate 287 AH 5.74 A
@ 20 Hour Rate 241 AH 12.05 A
@ 15 Hour Rate 229 AH 15.26 A
@ 10 Hour Rate 212 AH 21.21 A
@ 8 Hour Rate 207 AH 25.91 A
@ 5 Hour Rate 190 AH 38.08 A
@ 1 Hour Rate 96 AH 96.4 A

Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F).
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 31.5 kg 69.5 lbs
Length 25.9 cm 10.19"
Width 18.1 cm 7.13"
Height Inc. Term. 27.9 cm 11"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Electrolyte Reserve 57 mm 2.25"
Container Polypropylene
Cover Polypropylene
Handles Top Molded Strap Brackets

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

Rev.#1 | March 2019